Kaltis in French Kaltis in German Kaltis in Spanish
About Us News & Events Products Where To Buy FAQ Support Certificates Contact Sitemap
Kaltis freezer products

Kaltis® Products

Comparative Chart

Refrigeration System

ANSI and DIN Standard Dimension
  Prime Merit Benefit
Operating Temperature -86°C -40°C -86°C -40°C  
Single Refrigeration System   yes   yes High Efficiency
Cascade System yes   yes   Stable, Reliable
Industry-Grade Refrigeration Compressor yes yes yes yes High Efficiency, Energy Saving
CFC-Free Refrigerants yes yes yes yes Environmentally Friendly
High Cascade Refrigerant yes yes yes yes HFC series
Low Cascade Refrigerant yes   yes   HFC series
Down feed Evaporator yes yes yes yes Smooth refrigerant flow
Washable condenser filter yes yes yes yes Ensures optimum cooling
Enhanced Condenser yes yes yes yes Optimum Cooling

Controller

ANSI and DIN Standard Dimension
  Prime Merit Benefit
Operating Temperature -86°C -40°C -86°C -40°C  
Microprocessor yes yes yes yes Accurate control
Password Protection yes yes yes yes Start-up and setting security
Independent high/ low alarm yes yes yes yes Simple to set

Back Top

Power Supply

ANSI and DIN Standard Dimension
  Prime Merit Benefit
Operating Temperature -86°C -40°C -86°C -40°C  
Circuit Breaker yes yes yes yes Protects Power Supply Circuit
Automatic Voltage Regulator yes yes yes yes Provides Stable Voltage
Surge Protection yes yes yes yes Protects control system
Digital Voltage Monitoring yes yes     Detect voltage after the regulator in real time
Digital Current Monitoring yes yes     Monitors current in real time
Solid State Relay yes yes yes yes Extends controller life
Automatic restart delay yes yes yes yes Ensures power quality

Alarm System

ANSI and DIN Standard Dimension
  Prime Merit Benefit
Operating Temperature -86°C -40°C -86°C -40°C  
Intelligent Self-Diagnostics yes yes yes yes Automatically confirms alarm event.
Icon Display yes yes     Visual Display
Alarm Code 22 18 12 10 Directly displays alarm status
Audio Alarm yes yes yes yes Temperature or power failure
Alarm backup battery yes yes yes yes For monitoring of alarm system.
Alarm Test yes yes yes yes Test alarm function
RS232 communication port yes yes Optional Optional Software for PC, data logging
RS485 communication port Optional Optional Optional Optional Software for PC, data logging
Remote alarm contact yes yes yes yes Additional protection of alarm contact

Back Top

Monitoring System

ANSI and DIN Standard Dimension
  Prime Merit Benefit
Operating Temperature -86°C -40°C -86°C -40°C  
Chamber temperature yes yes yes yes Independent high/low alarm
Door Open yes yes yes yes Sounds when door is open/closed
Compressor Protection yes yes     Self adjusting, extending compressor life
High Ambient Temperature yes yes     High ambient temperature conditions
Low Condensation yes yes yes yes Auto dial alarm (optional)
Filter Condition yes yes     Advises when filter requires replacement
Power failure yes yes yes yes Alarm sounds on power failure
Voltage Fluctuations / supply Monitor yes yes     Monitors post-regulator voltage fluctuations
Circuit Breaker yes yes     Circuit Protection

Cabinets (All Models)

ANSI and DIN Standard Dimension
  Prime Merit Benefit
Operating Temperature -86°C -40°C -86°C -40°C  
Urethane insulation yes yes yes yes Low K value (Thermal
conductivity rate)
RS485 Communications Port yes yes yes yes On Line Monitoring
Internal Rounded corners yes yes yes yes Easy to clean.
General Insulation yes yes yes yes Reduces freezer noise
levels and compressor noise
Heavy duty castors/
Leveling Feet
yes yes yes yes Facilitates moving and leveling

Back Top

Upright Models

ANSI and DIN Standard Dimension
  Prime Merit Benefit
Operating Temperature -86°C -40°C -86°C -40°C  
Eye Level Controller yes yes yes yes User friendly, easy to read.
Low Profile Design yes yes yes yes Only 200cm (78.7" tall)
Three adjustable shelves
and four or five inner doors
yes yes yes yes Maximum internal space,
and access convenience
Pull 'N' Push latch and
handle Independent,
insulated inner doors
yes yes yes yes Easy to use

Chest Models

ANSI and DIN Standard Dimension
  Prime Merit Benefit
Operating Temperature -86°C -40°C -86°C -40°C  
Low profile design yes yes yes yes Easy access to inventory
Counter-balanced hinges yes yes yes yes Easy to open
Insulated interior-lids yes yes yes yes Greater sample protection

* Specifications are subject to change without notice

 

Back Top