Minerva™ Microprocessor Controller

Minerva™ microprocessor controllers provide system control, electronic, alarm and monitoring functions. Minerva™ guarantees the highest level of sample protection.

Minerva™ constantly scans ambient conditions and the refrigeration systems. Iinformation is immediately sent to the controller, ensuring optimum temperature control and minimum power consumption.

Merit Series

Please click on each icon on the controller panel to see its function.

Merit microprocessor controller Setting Adjustment buttons Scroll for function I/O key I/O indicator Alarm indicator Alarm Mute Alarm Test Temperature Deviation Door Ajar membrane keypad

Membrane Keypad

To display and enter all settings, parameters, and alarm history. Settings are user-settable and password protected. Can also be set with the optional Personal Identification System.

I/O Key

  • 4 digit password security
  • Stops or starts freezer by keying in a 4- digit password.

I/O Indicator

Displays freezer parameters on start up.

Alarm indicator

Displays alarm events.

Alarm Mute

Mutes the alarm.

Alarm Test

Tests the visual and audio alarms.

Temperature Deviation

Lights up when the chamber temperature is over range.

Power failure

Lights up after a power failure.

Condenser Control

Monitors condenser status and makes adjustments.

Door Ajar

Monitors outer door status: When open for too long , or not properly closed, an alarm will sound.

Battery Alarm

Sounds depending on the power status. Battery alarm will sound after a power failure.

LN2/LCO2 Backup system

Optional, factory installed. Must be specified with order.

Power Monitor

Monitors on line power supply to the unit.

Voltage Monitor

Monitors and adjusts post-regulator voltage error.

Scroll for function parameters

Setting Adjustment buttons

 

Back Top

Minerva™ Microprocessor Controller Merit Series Features

Intelligent Self-Diagnosis (I.S.D)

System controller monitors and displays the operating parameters and makes any adjustments, should this become necessary.

Digital Display

Easy to read, multifunction LCD Digital display.

Audible & Visual Alarms

Automatic activation following an alarm event.

Automatic Delay Restart (ADR)

Auto restart delay: Ensures on line quality after power failure, decreases power load, and protects the compressor.

Voltage Monitor

Monitors voltage

Amperage Monitor

Monitors current in real-time.

Real Time Clock (RTC)

Built in clock: Confirms the alarm time and highest temperature.

Event Recorder

Records alarm, temperature & time

Auto Restart

Automatic restart and system re-set after a power failure.

Security Level

Standard - (4 digit password)
Optional-? Personal Identification System

Heavy Load Mode

Automatically activated to decrease compressor load, extending compressor life.